BUSINESS
Engineering
The engineering business offers a wide range of services based to customer needs, including cleanroom and related cooling, air conditioning, and exhaust systems, as well as process cooling and air conditioning systems for factories and commercial facilities. We are responsible for all aspects of our work, from current status surveys to design, procurement, construction, commissioning, and maintenance.
Clean Room Construction
We handle the engineering and construction of Class 10 clean rooms required for semiconductor manufacturing.
HVAC System Construction
We handle HVAC work for various factories including clean rooms and commercial facilities.
Special Requirement
We handle the design, manufacture, and maintenance of special equipment according to customer requests.
Testing & Commissioning
We take responsibility by testing and commissioning that the designed and constructed equipment and machinery meets the customer's requirements.
Chiller Sales
The chiller sales business provides high-performance chillers to meet cooling needs.
With a diverse product line ranging from industrial to commercial applications, we propose cooling solutions that best meet customer requirements.
Product Line Up
Conventional Chiller
ETI
ETI
Capacity; 150-700Rt
Refrigerant; R134a
MyHIJAU; Registered
Built-in Inverter
GART, GART-I
GART, GART-I
Capacity; 400-6000Rt
Refrigerant; R134a
MyHIJAU; Registered
DOSH applicable
GART-R/P,
GART-RI/PI
GART-R/P, GART-RI/PI
Capacity; 420-2700Rt
Refrigerant; R134a
MyHIJAU; Registered
New Refrigerant Chiller
GART-ZE,
GART-ZEI
GART-ZE, GART-ZEI
Capacity; 300-5000Rt
Refrigerant; R1234ze(E)
MyHIJAU; Registered
DOSH applicable
ETI-Z
ETI-Z
Capacity; 150-700Rt
Refrigerant; R1233zd(E)
MyHIJAU; Registered
Built-in Inverter
MyHIJAU; Malaysia's official green recognition
The heat exchanger of chiller unit may require DOSH certification as pressure vessel depending on the type, size, pressure, intended use, etc.
Services
The service business supports stable operation for delivered equipment and facilities, including regular maintenance and operational adjustments, part replacement/repair, data evaluation, etc.
MHI centrifugal chillers will be maintained by MHI-certified service staff, who will provide services tailored to long-term operation, including in-house compressor overhaul work.
Preventive Maintenance for MHI Chiller
- On Call Service
- Preventive Inspection
- Annual Maintenance
- Tube Cleaning
- Lubricant Oil Analysis / Replacement
- Vibration Measurement / Analysis on Compressor
- Eddy Current Test for Condenser / Evaporator
- Testing and Analysis (Electrical, Water & etc,)
- Compressor Overhaul